XER
Pump display Error
Possible causes
Type | Description | Solution |
---|---|---|
Power | The pump display connected to the X2 has either lost power or was never switched on. | Make sure the power supply is operational. |
Comms | The RS485 cable linking the X2 and the pump display is not connected properly at either end or is damaged. | Make sure the cable is connected the right way on each end and that it isn't damaged. |
Address | The X2 might be expecting to connect to a pump display address 1, for example, but the address on the pump display is set to something else. | Make sure to set the address as required. |
Environmental | The pump display itself became damaged from rain getting into the device or something similar and is no longer working properly. | Contact Hydip to get a replacement pump display. |
Firmware | An issue either in the X2 or the pump display's firmware. | Contact Hydip for assistance. |